FiT Rates for Solar PV (Community) (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 4kW
0.3552
(ii)
above 4kW and up to and including 24kW
0.3464
(iii)
above 24kW and up to and including 72kW
0.1673
(i)
up to and including 4kW
0.3947
(ii)
above 4kW and up to and including 24kW
0.3849
(iii)
above 24kW and up to and including 72kW
0.1968
(i)
up to and including 4kW
0.4385
(ii)
above 4kW and up to and including 24kW
0.4277
(iii)
above 24kW and up to and including 72kW
0.2315
(i)
up to and including 4kW
0.4872
(ii)
above 4kW and up to and including 24kW
0.4752
(iii)
above 24kW and up to and including 72kW
0.2724
(i)
up to and including 4kW
0.5413
(ii)
above 4kW and up to and including 24kW
0.5280
(iii)
above 24kW and up to and including 72kW
0.3205
(i)
up to and including 4kW
0.6014
(ii)
above 4kW and up to and including 24kW
0.5867
(iii)
above 24kW and up to and including 72kW
0.3770
(i)
up to and including 4kW
0.6682
(ii)
above 4kW and up to and including 24kW
0.6519
(iii)
above 24kW and up to and including 72kW
0.4435
(i)
up to and including 4kW
0.7424
(ii)
above 4kW and up to and including 24kW
0.7243
(iii)
above 24kW and up to and including 72kW
0.5218
(i)
up to and including 4kW
0.8249
(ii)
above 4kW and up to and including 24kW
0.8048
(iii)
above 24kW and up to and including 72kW
0.6139
(i)
up to and including 4kW
0.9166
(ii)
above 4kW and up to and including 24kW
0.8942
(iii)
above 24kW and up to and including 72kW
0.7646
(i)
up to and including 4kW
0.9166
(ii)
above 4kW and up to and including 24kW
0.8942
(iii)
above 24kW and up to and including 72kW
0.7222
(i)
up to and including 4kW
1.0184
(ii)
above 4kW and up to and including 24kW
0.9936
(b) Bonus FiT rates having the following criteria (one or more) :
(i)
use as installation in buildings or building structures
+0.0668
(ii)
use as building materials
+0.0222
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0742
(ii)
use as building materials
+0.0278
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0824
(ii)
use as building materials
+0.0347
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0915
(ii)
use as building materials
+0.0434
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1017
(ii)
use as building materials
+0.0542
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1130
(ii)
use as building materials
+0.0678
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1256
(ii)
use as building materials
+0.0848
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1395
(ii)
use as building materials
+0.1060
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1550
(ii)
use as building materials
+0.1325
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1938
(ii)
use as building materials
+0.1863
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1722
(ii)
use as building materials
+0.1656
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.2153
(ii)
use as building materials
+0.2070
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
FiT Rates for Solar PV (Individual) (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 4kW
0.3552
(ii)
above 4kW and up to and including 12kW
0.3464
(i)
up to and including 4kW
0.3947
(ii)
above 4kW and up to and including 12kW
0.3849
(i)
up to and including 4kW
0.4385
(ii)
above 4kW and up to and including 12kW
0.4277
(i)
up to and including 4kW
0.4872
(ii)
above 4kW and up to and including 12kW
0.4752
(i)
up to and including 4kW
0.5413
(ii)
above 4kW and up to and including 12kW
0.5280
(i)
up to and including 4kW
0.6014
(ii)
above 4kW and up to and including 12kW
0.5867
(i)
up to and including 4kW
0.6682
(ii)
above 4kW and up to and including 12kW
0.6519
(i)
up to and including 4kW
0.7424
(ii)
above 4kW and up to and including 12kW
0.7243
(i)
up to and including 4kW
0.8249
(ii)
above 4kW and up to and including 12kW
0.8048
(i)
up to and including 4kW
0.9166
(ii)
above 4kW and up to and including 12kW
0.8942
(i)
up to and including 4kW
1.0184
(ii)
above 4kW and up to and including 12kW
0.9936
(i)
up to and including 4kW
1.0411
(ii)
above 4kW and up to and including 24kW
1.0157
(iii)
above 24kW and up to and including 72kW
0.7552
(iv)
above 72kW and up to and including 1MW
0.7296
(v)
above 1MW and up to and including 10MW
0.6080
(vi)
above 10MW and up to and including 30MW
0.5440
(i)
up to and including 4kW
1.1316
(ii)
above 4kW and up to and including 24kW
1.1040
(iii)
above 24kW and up to and including 72kW
0.9440
(iv)
above 72kW and up to and including 1MW
0.9120
(v)
above 1MW and up to and including 10MW
0.7600
(vi)
above 10MW and up to and including 30MW
0.6800
(i)
up to and including 4kW
1.1316
(ii)
above 4kW and up to and including 24kW
1.1040
(iii)
above 24kW and up to and including 72kW
1.0856
(iv)
above 72kW and up to and including 1MW
1.0488
(v)
above 1MW and up to and including 10MW
0.8740
(vi)
above 10MW and up to and including 30MW
0.7820
(i)
up to and including 4kW
1.2300
(ii)
above 4kW and up to and including 24kW
1.2000
(iii)
above 24kW and up to and including 72kW
1.1800
(iv)
above 72kW and up to and including 1MW
1.1400
(v)
above 1MW and up to and including 10MW
0.9500
(vi)
above 10MW and up to and including 30MW
0.8500
(b) Bonus FiT rates having the following criteria (one or more) :
(i)
use as installation in buildings or building structures
+0.0668
(ii)
use as building materials
+0.0222
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0742
(ii)
use as building materials
+0.0278
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0824
(ii)
use as building materials
+0.0347
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0915
(ii)
use as building materials
+0.0434
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1017
(ii)
use as building materials
+0.0542
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1130
(ii)
use as building materials
+0.0678
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1256
(ii)
use as building materials
+0.0848
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1395
(ii)
use as building materials
+0.1060
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1550
(ii)
use as building materials
+0.1325
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1722
(ii)
use as building materials
+0.1656
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.2153
(ii)
use as building materials
+0.2070
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.2201
(ii)
use as building materials
+0.2116
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
(i)
use as installation in buildings or building structures
+0.2392
(ii)
use as building materials
+0.2300
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
(i)
use as installation in buildings or building structures
+0.2392
(ii)
use as building materials
+0.2300
(iii)
use of locally manufactured or assembled solar PV modules
+0.0276
(iv)
use of locally manufactured or assembled solar inverters
+0.0092
(i)
use as installation in buildings or building structures
+0.2600
(ii)
use as building materials
+0.2500
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
FiT Rates for Solar PV (Non-individual (≤ 500 kW)) (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 4kW
0.3552
(ii)
above 4kW and up to and including 24kW
0.3464
(iii)
above 24kW and up to and including 72kW
0.1673
(iv)
above 72kW and up to and including 1MW
0.1616
(i)
up to and including 4kW
0.3947
(ii)
above 4kW and up to and including 24kW
0.3849
(iii)
above 24kW and up to and including 72kW
0.1968
(iv)
above 72kW and up to and including 1MW
0.1901
(i)
up to and including 4kW
0.4385
(ii)
above 4kW and up to and including 24kW
0.4277
(iii)
above 24kW and up to and including 72kW
0.2315
(iv)
above 72kW and up to and including 1MW
0.2237
(i)
up to and including 4kW
0.4872
(ii)
above 4kW and up to and including 24kW
0.4752
(iii)
above 24kW and up to and including 72kW
0.2724
(iv)
above 72kW and up to and including 1MW
0.2632
(i)
up to and including 4kW
0.5413
(ii)
above 4kW and up to and including 24kW
0.5280
(iii)
above 24kW and up to and including 72kW
0.3205
(iv)
above 72kW and up to and including 1MW
0.3096
(i)
up to and including 4kW
0.6014
(ii)
above 4kW and up to and including 24kW
0.5867
(iii)
above 24kW and up to and including 72kW
0.3770
(iv)
above 72kW and up to and including 1MW
0.3642
(i)
up to and including 4kW
0.6682
(ii)
above 4kW and up to and including 24kW
0.6519
(iii)
above 24kW and up to and including 72kW
0.4435
(iv)
above 72kW and up to and including 1MW
0.4285
(i)
up to and including 4kW
0.7424
(ii)
above 4kW and up to and including 24kW
0.7243
(iii)
above 24kW and up to and including 72kW
0.5218
(iv)
above 72kW and up to and including 1MW
0.5041
(i)
up to and including 4kW
0.8249
(ii)
above 4kW and up to and including 24kW
0.8048
(iii)
above 24kW and up to and including 72kW
0.6139
(iv)
above 72kW and up to and including 1MW
0.5930
(v)
above 1MW and up to and including 10MW
0.4651
(vi)
above 10MW and up to and including 30MW
0.4162
(i)
up to and including 4kW
0.9166
(ii)
above 4kW and up to and including 24kW
0.8942
(iii)
above 24kW and up to and including 72kW
0.7222
(iv)
above 72kW and up to and including 1MW
0.6977
(v)
above 1MW and up to and including 10MW
0.5472
(vi)
above 10MW and up to and including 30MW
0.4896
(i)
up to and including 4kW
1.0184
(ii)
above 4kW and up to and including 24kW
0.9936
(iii)
above 24kW and up to and including 72kW
0.8496
(iv)
above 72kW and up to and including 1MW
0.8208
(v)
above 1MW and up to and including 10MW
0.6840
(vi)
above 10MW and up to and including 30MW
0.6120
(i)
up to and including 4kW
1.0411
(ii)
above 4kW and up to and including 24kW
1.0157
(iii)
above 24kW and up to and including 72kW
0.7552
(iv)
above 72kW and up to and including 1MW
0.7296
(v)
above 1MW and up to and including 10MW
0.6080
(vi)
above 10MW and up to and including 30MW
0.5440
(i)
up to and including 4kW
1.1316
(ii)
above 4kW and up to and including 24kW
1.1040
(iii)
above 24kW and up to and including 72kW
0.9440
(iv)
above 72kW and up to and including 1MW
0.9120
(v)
above 1MW and up to and including 10MW
0.7600
(vi)
above 10MW and up to and including 30MW
0.6800
(i)
up to and including 4kW
1.1316
(ii)
above 4kW and up to and including 24kW
1.1040
(iii)
above 24kW and up to and including 72kW
1.0856
(iv)
above 72kW and up to and including 1MW
1.0488
(v)
above 1MW and up to and including 10MW
0.8740
(vi)
above 10MW and up to and including 30MW
0.7820
(i)
up to and including 4kW
1.2300
(ii)
above 4kW and up to and including 24kW
1.2000
(iii)
above 24kW and up to and including 72kW
1.1800
(iv)
above 72kW and up to and including 1MW
1.1400
(v)
above 1MW and up to and including 10MW
0.9500
(vi)
above 10MW and up to and including 30MW
0.8500
(b) Bonus FiT rates having the following criteria (one or more) :
(i)
use as installation in buildings or building structures
+0.0668
(ii)
use as building materials
+0.0222
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0742
(ii)
use as building materials
+0.0278
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0824
(ii)
use as building materials
+0.0347
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0915
(ii)
use as building materials
+0.0434
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1017
(ii)
use as building materials
+0.0542
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1130
(ii)
use as building materials
+0.0678
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1256
(ii)
use as building materials
+0.0848
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1395
(ii)
use as building materials
+0.1060
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1550
(ii)
use as building materials
+0.1325
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1722
(ii)
use as building materials
+0.1656
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.2153
(ii)
use as building materials
+0.2070
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.2201
(ii)
use as building materials
+0.2116
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
(i)
use as installation in buildings or building structures
+0.2392
(ii)
use as building materials
+0.2300
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
(i)
use as installation in buildings or building structures
+0.2392
(ii)
use as building materials
+0.2300
(iii)
use of locally manufactured or assembled solar PV modules
+0.0276
(iv)
use of locally manufactured or assembled solar inverters
+0.0092
(i)
use as installation in buildings or building structures
+0.2600
(ii)
use as building materials
+0.2500
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
FiT Rates for Solar PV (Non-individual (> 500 kW)) (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 4kW
0.3552
(ii)
above 4kW and up to and including 24kW
0.3464
(iii)
above 24kW and up to and including 72kW
0.1673
(iv)
above 72kW and up to and including 1MW
0.1616
(i)
up to and including 4kW
0.3947
(ii)
above 4kW and up to and including 24kW
0.3849
(iii)
above 24kW and up to and including 72kW
0.1968
(iv)
above 72kW and up to and including 1MW
0.1901
(i)
up to and including 4kW
0.4385
(ii)
above 4kW and up to and including 24kW
0.4277
(iii)
above 24kW and up to and including 72kW
0.2315
(iv)
above 72kW and up to and including 1MW
0.2237
(i)
up to and including 4kW
0.4872
(ii)
above 4kW and up to and including 24kW
0.4752
(iii)
above 24kW and up to and including 72kW
0.2724
(iv)
above 72kW and up to and including 1MW
0.2632
(i)
up to and including 4kW
0.5413
(ii)
above 4kW and up to and including 24kW
0.5280
(iii)
above 24kW and up to and including 72kW
0.3205
(iv)
above 72kW and up to and including 1MW
0.3096
(i)
up to and including 4kW
0.6014
(ii)
above 4kW and up to and including 24kW
0.5867
(iii)
above 24kW and up to and including 72kW
0.3770
(iv)
above 72kW and up to and including 1MW
0.3642
(i)
up to and including 4kW
0.6682
(ii)
above 4kW and up to and including 24kW
0.6519
(iii)
above 24kW and up to and including 72kW
0.4435
(iv)
above 72kW and up to and including 1MW
0.4285
(i)
up to and including 4kW
0.7424
(ii)
above 4kW and up to and including 24kW
0.7243
(iii)
above 24kW and up to and including 72kW
0.5218
(iv)
above 72kW and up to and including 1MW
0.5041
(i)
up to and including 4kW
0.8249
(ii)
above 4kW and up to and including 24kW
0.8048
(iii)
above 24kW and up to and including 72kW
0.6139
(iv)
above 72kW and up to and including 1MW
0.5930
(v)
above 1MW and up to and including 10MW
0.4651
(vi)
above 10MW and up to and including 30MW
0.4162
(i)
up to and including 4kW
0.9166
(ii)
above 4kW and up to and including 24kW
0.8942
(iii)
above 24kW and up to and including 72kW
0.7222
(iv)
above 72kW and up to and including 1MW
0.6977
(v)
above 1MW and up to and including 10MW
0.5472
(vi)
above 10MW and up to and including 30MW
0.4896
(i)
up to and including 4kW
1.0184
(ii)
above 4kW and up to and including 24kW
0.9936
(iii)
above 24kW and up to and including 72kW
0.8496
(iv)
above 72kW and up to and including 1MW
0.8208
(v)
above 1MW and up to and including 10MW
0.6840
(vi)
above 10MW and up to and including 30MW
0.6120
(i)
up to and including 4kW
1.0411
(ii)
above 4kW and up to and including 24kW
1.0157
(iii)
above 24kW and up to and including 72kW
0.7552
(iv)
above 72kW and up to and including 1MW
0.7296
(v)
above 1MW and up to and including 10MW
0.6080
(vi)
above 10MW and up to and including 30MW
0.5440
(i)
up to and including 4kW
1.1316
(ii)
above 4kW and up to and including 24kW
1.1040
(iii)
above 24kW and up to and including 72kW
0.9440
(iv)
above 72kW and up to and including 1MW
0.9120
(v)
above 1MW and up to and including 10MW
0.7600
(vi)
above 10MW and up to and including 30MW
0.6800
(i)
up to and including 4kW
1.1316
(ii)
above 4kW and up to and including 24kW
1.1040
(iii)
above 24kW and up to and including 72kW
1.0856
(iv)
above 72kW and up to and including 1MW
1.0488
(v)
above 1MW and up to and including 10MW
0.8740
(vi)
above 10MW and up to and including 30MW
0.7820
(i)
up to and including 4kW
1.2300
(ii)
above 4kW and up to and including 24kW
1.2000
(iii)
above 24kW and up to and including 72kW
1.1800
(iv)
above 72kW and up to and including 1MW
1.1400
(v)
above 1MW and up to and including 10MW
0.9500
(vi)
above 10MW and up to and including 30MW
0.8500
(b) Bonus FiT rates having the following criteria (one or more) :
(i)
use as installation in buildings or building structures
+0.0668
(ii)
use as building materials
+0.0222
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0742
(ii)
use as building materials
+0.0278
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0824
(ii)
use as building materials
+0.0347
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.0915
(ii)
use as building materials
+0.0434
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1017
(ii)
use as building materials
+0.0542
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1130
(ii)
use as building materials
+0.0678
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1256
(ii)
use as building materials
+0.0848
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1395
(ii)
use as building materials
+0.1060
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1550
(ii)
use as building materials
+0.1325
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.1722
(ii)
use as building materials
+0.1656
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.2153
(ii)
use as building materials
+0.2070
(iii)
use of locally manufactured or assembled solar PV modules
+0.0500
(iv)
use of locally manufactured or assembled solar inverters
+0.0500
(i)
use as installation in buildings or building structures
+0.2201
(ii)
use as building materials
+0.2116
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
(i)
use as installation in buildings or building structures
+0.2392
(ii)
use as building materials
+0.2300
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
(i)
use as installation in buildings or building structures
+0.2392
(ii)
use as building materials
+0.2300
(iii)
use of locally manufactured or assembled solar PV modules
+0.0276
(iv)
use of locally manufactured or assembled solar inverters
+0.0092
(i)
use as installation in buildings or building structures
+0.2600
(ii)
use as building materials
+0.2500
(iii)
use of locally manufactured or assembled solar PV modules
+0.0300
(iv)
use of locally manufactured or assembled solar inverters
+0.0100
FiT Rates for Biogas (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3200
(ii)
above 4MW and up to and including 10MW
0.3000
(iii)
above 10MW and up to and including 30MW
0.2800
(b) Bonus FiT rates having the following criteria (one or more) :
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0000
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0000
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0000
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0000
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0000
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0000
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0100
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0200
(ii)
use of locally manufactured or assembled gas engine technology
+0.0100
FiT Rates for Biogas ( Landfill / Agri Waste ) (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 5MW
0.2814
(i)
up to and including 5MW
0.2814
(i)
up to and including 5MW
0.2210 - 0.2814
(i)
up to and including 5MW
0.2210 - 0.2814
(i)
up to and including 5MW
0.2210 - 0.2814
(i)
up to and including 5MW
0.2210 - 0.2814
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3184
(ii)
above 4MW and up to and including 10MW
0.2985
(iii)
above 10MW and up to and including 30MW
0.2786
(i)
up to and including 4MW
0.3200
(ii)
above 4MW and up to and including 10MW
0.3000
(iii)
above 10MW and up to and including 30MW
0.2800
(b) Bonus FiT rates having the following criteria (one or more) :
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0500
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0199
(ii)
use of locally manufactured or assembled gas engine technology
+0.0100
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0786
(i)
use of gas engine technology with electrical efficiency of above 40%
+0.0200
(ii)
use of locally manufactured or assembled gas engine technology
+0.0100
(iii)
use of landfill, sewage gas or agricultural waste including animal waste as fuel source
+0.0800
FiT Rates for Biomass (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 30MW
0.2900
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 30MW
0.2350 - 0.290
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3100
(ii)
above 10MW and up to and including 20MW
0.2900
(iii)
above 20MW and up to and including 30MW
0.2700
(b) Bonus FiT rates having the following criteria (one or more) :
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0100
(i)
use of gasification technology
+0.0200
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0100
FiT Rates for Biomass ( Solid Waste ) (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 30MW
0.2900
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 30MW
0.2350 - 0.290
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3085
(ii)
above 10MW and up to and including 20MW
0.2886
(iii)
above 20MW and up to and including 30MW
0.2687
(i)
up to and including 10MW
0.3100
(ii)
above 10MW and up to and including 20MW
0.2900
(iii)
above 20MW and up to and including 30MW
0.2700
(b) Bonus FiT rates having the following criteria (one or more) :
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0000
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0982
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0982
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0982
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0982
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0982
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0500
(iv)
use of solid waste as fuel source
+0.0982
(i)
use of gasification technology
+0.0199
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0100
(iv)
use of solid waste as fuel source
+0.0982
(i)
use of gasification technology
+0.0200
(ii)
use of steam-based electricity generating systems with overall efficiency of above 20%
+0.0100
(iii)
use of locally manufactured or assembled boiler or gasifier
+0.0100
(iv)
use of solid waste as fuel source
+0.1000
FiT Rates for Small Hydro (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 2MW
0.2600
(ii)
above 2MW and up to and including 10MW
0.2500
(iii)
above 10MW and up to and including 30MW
0.2400
(i)
up to and including 10MW
0.2400
(ii)
above 10MW and up to and including 30MW
0.2300
(i)
up to and including 10MW
0.2400
(ii)
above 10MW and up to and including 30MW
0.2300
(i)
up to and including 10MW
0.2400
(ii)
above 10MW and up to and including 30MW
0.2300
(i)
up to and including 10MW
0.2400
(ii)
above 10MW and up to and including 30MW
0.2300
FiT Rates for Small Hydro (high Head) (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 30MW
0.2599
(i)
up to and including 30MW
0.2249 - 0.2599
(i)
up to and including 30MW
0.2288 - 0.2599
(i)
up to and including 30MW
0.2300 - 0.2599
FiT Rates for Small Hydro (low Head) (21 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 30MW
0.2900
(i)
up to and including 30MW
0.2650 - 0.2900
(i)
up to and including 30MW
0.2749 - 0.2900
(i)
up to and including 30MW
0.2749 - 0.2900
FiT Rates for Geothermal (16 years from FiT Commencement Date)
Description of Qualifying Renewable Energy Installation FiT Rates (RM per kWh)
(a) Basic FiT rates having installed capacity of :
(i)
up to and including 30MW
0.4500